Made available to the public under the provisions of the Bureau of Indian Standards Act of 1986 and the Right to Information Act of 2005. In order to promote public education and public safety, equal justice for all, a better informed citizenry, the rule of law, world trade and world peace, this legal document is hereby made available on a noncommercial basis, as it is the right of all humans to know and speak the laws that govern them.
Division Name: Electrotechnical
Section Name: Winding Wire (ETD 33)
Standard | Year | Title | IBR |
---|---|---|---|
IS 482 (pdf) IS 482 (txt) | 1981 | Reels for Covered Round Electrical Winding Wires | |
IS 2069 (pdf) | 1991 | Drums for covered winding wires and strips for electrical purpose | |
IS 4685-1 (pdf) | 1968 | Varnish bonded glass-fibre covered copper conductors, Part 1: Round wires | |
IS 5825 (pdf) IS 5825 (txt) | 1993 | Test procedure for the determination of the temperature index of enamelled winding wires | IEC Pub 172 |
IS 6162-1 (pdf) | 1971 | Paper-Covered Aluminium Conductors, Part I: Round Conductors | IEC 60111 |
IS 6162-2 (pdf) | 1971 | Paper Covered Aluminium Conductors, Part II: Rectangular Conductors | IEC 60111 |
IS 6181 (pdf) | 1971 | Varnish Bonded Glass-Fibre Braided Rectangular Copper Conductors | |
IS 7391-1 (pdf) | 1974 | Cotton covered copper conductors, Part 1: Round conductors | IEC 60182 |
IS 7391-2 (pdf) IS 7391-2 (txt) | 1974 | Cotton covered copper conductors, Part 2: Rectangular conductors | |
IS 7404-1 (pdf) IS 7404-1 (txt) | 1991 | Paper Covered Copper Conductors, Part 1: Round Conductors | |
IS 7576 (pdf) IS 7576 (txt) | 1974 | Bunched enamelled copper conductors with silk covering | IEC 60317-1 |
IS 8572 (pdf) IS 8572 (txt) | 1993 | Paper covered flexible/stranded copper conductors for transformer leads | |
IS 8783-1 (pdf) | 1995 | Winding wires for submersible motors, Part 1: Conductor data | |
IS 8783-2 (pdf) IS 8783-2 (txt) | 1995 | Winding wires for submersible motors, Part 2: Materials for dielectric and jacket | |
IS 8783-3 (pdf) IS 8783-3 (txt) | 1995 | Winding wires for submersible motors, Part 3: Methods of tests | |
IS 8783-4-1 (pdf) IS 8783-4-1 (txt) | 1995 | Winding Wires for Submersible Motors, Part 4: Individual Wires, Section 1: HR PVC Insulated Wires | |
IS 8783-4-2 (pdf) IS 8783-4-2 (txt) | 1995 | Winding Wires for Submersible Motors, Part 4: Individual Wires, Section 2: Crosslinked Polyethylene Insulated and Polymide jacketed wires | |
IS 8783-4-3 (pdf) | 1995 | Winding Wires for Submersible Motors, Part 4: Individual Wires, Section 3: Polyester and Polypropylene Insulated Winding Wires | |
IS 9148 (pdf) | 1979 | Tape wrapped rectangular and square copper wires with a temperature index of 220 | |
IS 9778 (pdf) IS 9778 (txt) | 1981 | Guide for evaluation of thermal endurance of varnish bonded glass-fibre covered rectangular copper conductors | |
IS 10031 (pdf) | 1981 | Taper barreled delivery spools for covered round electrical winding wires | IEC 60264-3 |
IS 11174 (pdf) IS 11174 (txt) | 1984 | Aromatic polyamide paper covered rectangular and square copper wires with temperature index 200 | |
IS 11184 (pdf) IS 11184 (txt) | 1984 | Enamelled and varnish bonded glass fibre covered round copper wires | |
IS 11395 (pdf) IS 11395 (txt) | 1985 | Tape wrapped round copper wires with temperature index of 220 | |
IS 11597 (pdf) IS 11597 (txt) | 1986 | Polyester tape wrapped, varnish bonded glass-fibre covered rectangular paper conductors | |
IS 13343 (pdf) IS 13343 (txt) | 1992 | Guide for Thermal Endurance of Enamelled and Varnish Bonded Glass Covered Rectangular Copper Conductor | |
IS 13730-0-1 (pdf) | 2012 | Specifications for Particular Types of Winding Wires, Part 0: General Requirements, Section 1: Enamelled Round Copper Wire | IEC 60317-0-1 |
IS 13730-0-2 (pdf) IS 13730-0-2 (txt) | 2011 | Specifications for Particular Types of Winding Wires, Part 0: General Requirements, Section 2: Enamelled Rectangular Copper Wire | IEC Pub 317-0-2:1990 |
IS 13730-0-3 (pdf) IS 13730-0-3 (txt) | 2012 | Specifications for Particular Types of Winding Wires, Part 0: General Requirements, Section 3: Enamelled Round Aluminium Wire | IEC 60317-0-3:2008 |
IS 13730-0-4 (pdf) IS 13730-0-4 (txt) | 2011 | Specifications for Particular Types of Winding Wires, Part 0: General Requirements, Section 4: Glass-Fibre Wound Resin or Varish impregnated Bare or enamelled rectangular copper wire | IEC Pub 317-0-4:1990 |
IS 13730-0-5 (pdf) IS 13730-0-5 (txt) | 2012 | Particular Types of Winding Wires, Part 0: General Requirements, Section 5: Glass-Fibre Braided Resin or Varnish Impregnated, Bare or Enamelled Rectangular Copper Wire | IEC 60317-0-5:2006 |
IS 13730-0-6 (pdf) IS 13730-0-6 (txt) | 2012 | Specification for Particular Types of Winding Wires, Part 0: General Requirements, Section 6: Glass-Fibre Wound Resin or Varnish Impregnated, Bare or Enamelled Round Copper Wire | IEC 60317-3-6:2007 |
IS 13730-2 (pdf) IS 13730-2 (txt) | 2012 | Specifications for Particular Types of Winding Wires, Part 2: Solderable Polyurethane Enamelled Round Copper Wire, Class 130, with a Bonding Layer | IEC 60317-2:2000 |
IS 13730-3 (pdf) IS 13730-3 (txt) | 2012 | Specifications for Particular Types of Winding Wires, Part 3: Polyester Enamelled Round Copper Wire, Class 155 | IEC 60317-3:2004 |
IS 13730-8 (pdf) IS 13730-8 (txt) | 1996 | particular types of winding wires, Part 8: polyesterimide enamelled round copper wire class 180 | IEC 317-8 |
IS 13730-9 (pdf) | 1994 | particular types of winding wires, Part 09: Polyester enamelled round aluminium wire, Class 130 | |
IS 13730-13 (pdf) IS 13730-13 (txt) | 1993 | Particular types of winding wires, Part 13: Polyester or polyesterimide overcoated with polyamide-imide enamelled round copper wire, Class 200 | IEC Pub 317-13 |
IS 13730-15 (pdf) | 1994 | Particular types of winding wires, Part 15: Polyesterimide enamelled round aluminium wire, Class 180 | IEC Pub 317-15 |
IS 13730-16 (pdf) | 1996 | Particular types of winding wires, Part 16: Polyester enamelled rectangular copper wire, Class 155 | IEC 317-16 |
IS 13730-17 (pdf) IS 13730-17 (txt) | 1996 | particular types of winding wires, Part 17: Polyvinyl acetal enamelled rectangular copper wire, Class 105 | IEC 317-17 |
IS 13730-20 (pdf) IS 13730-20 (txt) | 1993 | Particular types of winding wires, Part 20: Solderable polyurethane enamelled round copper wire, Class 155 | IEC Pub 317-20 |
IS 13730-26 (pdf) IS 13730-26 (txt) | 1996 | particular types of winding wires, Part 26: Polymide-imide enamelled round copper wire, Class 200 | IEC 317-26 |
IS 13730-27 (pdf) | 1996 | Specifications for Particular Types of Winding Wires, Part 27: Paper Covered Rectangular Copper Wire | IEC 317-27 |
IS 13730-28 (pdf) IS 13730-28 (txt) | 1996 | particular types of winding wires, Part 28: Polyesterimide enamelled rectangular copper wire, Class 180 | IEC 317-28 |
IS 13730-29 (pdf) IS 13730-29 (txt) | 1996 | Specifications for Particular Types of Winding Wires, Part 29: Polyester or Polyesterimide Overcoated with Polyamide-imide Enamelled Rectangular Copper Wire, Class 200 | IEC 317-29 |
IS 13730-31 (pdf) IS 13730-31 (txt) | 1997 | Specifications for Particular Types of Winding Wires, Part 31: Glass-fibre Wound, Polyester or Polyesterimide Varnish-treated, Bare or En enamelled rectangular copper wire, temperature index 180 | IEC 317-31 |
IS 13730-32 (pdf) IS 13730-32 (txt) | 1997 | particular types of winding wires, Part 32: Glass-fibre wound, polyester or polyesterimide varnish-treated, bare or enamelled rectangular copper wire, temperature index 155 | IEC 317-32 |
IS 13730-33 (pdf) IS 13730-33 (txt) | 1997 | particular types of winding wieres, Part 33: Glass-fibre wound, silicone varnish treated bare or enamelled rectangular copper wire, temperature, index 200 | IEC 317-33 |
IS 13730-34 (pdf) IS 13730-34 (txt) | 2000 | Specifications for Particular Types of Winding Wires, Part 34: Polyester Enamelled Round Copper Wire, class 130 L | IEC Pub 317-34 |
IS 13730-39 (pdf) IS 13730-39 (txt) | 2005 | Specifications for particular types of winding wires, Part 39: Glass-fibre braided, polyester or polyesterimide varnish-treated, bare or enamelled rectangular copper wire, temperature index 180 | IEC 60317-39 |
IS 13730-43 (pdf) IS 13730-43 (txt) | 2005 | Specifications for particular types of winding wires, Part 43: Aromatic polymide tape wrapped round copper wires, Class 240 | IEC 60317-3 |
IS 13730-44 (pdf) IS 13730-44 (txt) | 2005 | Specifications for particular types of winding wires, Part 44: Aromatic polyimide tape wrapped rectangular Coo0per wire, Class 240 | IEC 60317-44 |
IS 13730-45 (pdf) IS 13730-45 (txt) | 1999 | Specifications for Particular Types of Winding Wires, Part 45: Polyester Enamelled Round Copper Wire, Class 130 | IEC 60317-45 |
IS 13730-48 (pdf) IS 13730-48 (txt) | 2005 | Specifications for particular types of winding wires : Part 48 Glass-fibre wound resin or varnish-impregnated, bare or enamelled round copper wire, temperature index 155 | IEC 60317-48 |
IS 13730-49 (pdf) IS 13730-49 (txt) | 2005 | Specifications for particular types of winding wires : Part 49 Glass-fibre wound resin or varnish-impregnated, bare or enamelled round copper wire, temperature index 180 | IEC 60317-49 |
IS 13730-50 (pdf) IS 13730-50 (txt) | 2005 | particular types of winding wires, Part 50: Glass-Fibre Wound Resin or Varnish-impregnated, bare or enamelled round copper wire, temperature index 200 | IEC 60317-50 |
IS 13730-53 (pdf) IS 13730-53 (txt) | 2005 | particular types of winding wires, Part 53: Aromatic polyimide (Aramid) tape wrapped rectangular copper wire, temperature Index 220 | IEC 60317-53 |
IS 13778-1 (pdf) IS 13778-1 (txt) | 2011 | WINDING WIRES - TEST METHODS | |
IS 13778-2 (pdf) | 1993 | Methods of test for winding wires, Part 2: Determination of dimensions | EC 60851-2:1985 |
IS 13778-2 (pdf) IS 13778-2 (txt) | 2013 | Methods of test for winding wires, Part 2: Determination of dimensions | EC 60851-2:2009 |
IS 13778-3 (pdf) IS 13778-3 (txt) | 2012 | Winding wires - Test methods, Part 3: Mechnical Properties | IEC 60851-3:2009 |
IS 13778-4 (pdf) IS 13778-4 (txt) | 2011 | Winding Wires - Test Methods, Part 4: Chemical properties | IEC 60851-4:2005 |
IS 13778-5 (pdf) IS 13778-5 (txt) | 2012 | Winding Wires - Test Methods, Part 5: Electrical Properties | IEC 60851-5:2008 |
IS 13778-6 (pdf) | 2011 | Winding Wires - Test Methods, Part 6: Thermal properties | IEC 60851-6:1996 |
IS 14841-2-1 (pdf) | 2000 | Packaging of Winding Wires, Part 2: Cylindrical Barrelled Delivery Spools, Section 1: Basic Dimensions | IEC 60264-2-1 |
IS 14841-2-2 (pdf) IS 14841-2-2 (txt) | 2000 | Packaging of Winding Wires, Part 2: Cylindrical Barrelled Delivery Spools, Section 2: Returnable Spools Made from Thermoplastic Materials | IEC 60264-2-2 |
IS 14841-3-1 (pdf) | 2000 | Packaging of Winding Wires, Part 3: Taper Barrelled Delivery Spools, Section 1: Basic Dimensions | IEC 60264-3-1 |
IS 14841-3-2 (pdf) IS 14841-3-2 (txt) | 2000 | Packaging of Winding Wires, Part 3: Taper Barrelled Delivery Spools, Section 2: Returnable Spools Made from Thermoplastic Materials | IEC 60264-3-2 |
IS 14841-3-3 (pdf) IS 14841-3-3 (txt) | 2000 | Packaging of Winding Wires, Part 3: Taper Barrelled Delivery Spools, Section 3: Non-returnable Spools Made from Thermoplastic Material | IEC 60264-3-3 |
IS 14841-3-4 (pdf) | 2000 | Packaging of Winding Wires, Part 3: Taper Barrelled Delivery Spools, Section 4: Basic Dimensions of Containers for Taper Barrelled Delivery Spools | IEC 60264-3-4 |
IS 14841-4-1 (pdf) IS 14841-4-1 (txt) | 2000 | Packaging of Winding Wires, Part 4: Methods of Test, Section 1: Delivery Spools Made from Thermoplastic Materials | IEC 60264-4-1 |
Last Updated: October 9, 2013
↑